- Carlor's heating is an electric preheating system designed for heat engines with water cooling. It is a universal, reliable, easy-to-install system that does not require any maintenance.
- 6- or 9-KW heaters are designed to equip high-power motors in stationary (electrics groups) or mobile (diesel locomotives) industrial applications. The heating may either be operated a few hours prior to the starting of the motor or operate on standby so as to permanently maintain the motor at the desired temperature. This guarantees ease of ignition irrespective of ambient temperature and enables prevention of mechanical breakdown linked to ignition from cold.
Système électrique 400 Volts + N 6 & 9 Kw
 |
|

- Heating assembly - Base - Hoods
All-aluminium construction for many years of service.
Shock- and corrosion-resistant.
Perfect enclosure of heating assembly.
Admitted diameter: 3/4".
- Regulation thermostat for water temp.
Adjustable range from 0 to 80°C (32°F to 176°F).
Interrupting capacity: 16 A.
- Cut-out thermostat
Protection in the event of overheating.
Manual reset.
Temperature measured at the level of the heating element for immediate reaction.
Interrupting capacity: 25 A.
Temperature setting: 110 °C (230°F).
- Circulation pump for water circuit
Allows rapid and homogeneous heating of all engine parts. Considerably increases the useful life of the heating assembly.
Enclosure rating IP44.
Unblockable motor. Wet pit pump.
Max. electrical power: 80 Watts
Single-phase tension: 230 Volts.
Frequency: 50 Hertz(CE) or 60 Hz(UL/CSA).
Maximum output: 3,500 litres/hour
Electric system 400 Volts + N 6 & 9 KW

|